Skip to main content

Person

Johanna M Nevitt

Research Geophysicist

Earthquake Science Center

Email: jnevitt@usgs.gov
Office Phone: 650-439-2461
ORCID: 0000-0003-3819-1773

Location
Moffett Field - Building 19
345 Middlefield Rd

Supervisor: Andrew J Barbour
thumbnail
In November 2016, the U.S. Geological Survey acquired high-resolution P- and S-wave seismic data across the surface trace of the West Napa Fault zone at Saintsbury Winery in Napa, California. We acquired seismic reflection, refraction, and guided-wave data along a 115-m-long profile across the known surface rupture zone of the West Napa Fault zone. To acquire the reflection and refraction data, we co-located shots and geophones, spaced every meter along the profile. We used 116 SercelTM L40A P-wave (40-Hz vertical-component) geophones with a sensitivity of 22.34 volts/meter/second to record 116 P-wave shots. We also used 116 SercelTM L28-LBH S-wave (4.5-Hz horizontal-component) geophones with a sensitivity of...
thumbnail
In April of 2021, the U.S. Geological Survey conducted a high-resolution seismic survey at Mee Ranch in Monterey County, California. Both passive- and active-source seismic data were acquired using DTCC SmartSolo 3-component nodal seismograph systems ("nodes"), which continuously recorded data at rates up to 2000 samples per second. For passive-source acquisition, a 6x5 grid of nodes was deployed for several weeks before and during the active source shooting. For active-source acquisition, 395 nodes were deployed 1 meter apart (2 meters apart near the endpoints) along a southwest-northeast trend to create an approximately 500-m-long linear array. Additional nodes were deployed at 1 or 2 meter spacing along 25- and...
thumbnail
In November 2016, the U.S. Geological Survey acquired high-resolution P- and S-wave seismic data across the surface trace of the West Napa Fault zone near Buhman Avenue in Napa, California. We acquired seismic reflection, refraction, and guided-wave data along a 117-m-long profile across the known surface rupture zone of the West Napa Fault zone. To acquire the reflection and refraction data, we co-located shots and geophones, spaced every meter along the profile. We used 118 SercelTM L40A P-wave (40-Hz vertical-component) geophones with a sensitivity of 22.34 volts/meter/second to record 118 P-wave shots. We also used 118 SercelTM L28-LBH S-wave (4.5-Hz horizontal-component) geophones with a sensitivity of 31.3...
ScienceBase brings together the best information it can find about USGS researchers and offices to show connections to publications, projects, and data. We are still working to improve this process and information is by no means complete. If you don't see everything you know is associated with you, a colleague, or your office, please be patient while we work to connect the dots. Feel free to contact sciencebase@usgs.gov.