This data release presents pumping rate data, water-level drawdown and recovery data, and atmospheric pressure data collected during 48 pumping tests conducted in 2015 and 2016 for a hydraulic tomography field experiment in the mudstone aquifer underlying the former Naval Air Warfare Center (NAWC), West Trenton, NJ. The pumping rate data include rates measured by in-line flow meters and rates measured manually by recording the time to fill a known volume with the pump discharge water. The water-level drawdown data include drawdowns measured by fiber-optic pressure transducers, and drawdowns measured by strain-gauge transducers. For many tests, water-level recovery data are also provided, which measure the change...
|