135 samples were assayed for gold by inductive coupled plasma-atomic emission spectroscopy following a 30g fire assay fusion (FA-ICP), after four-acid, near-total digestion. Trace-element geochemical analyses were performed by inductive coupled plasma-atomic emission spectroscopy (ICP-AES) methods after four-acid, near-total digestion. This method of digestion is possibly incomplete for some elements and may result in lower analytical results for these elements. See publication for a listing of these elements.