These data were collected using a 1200 kHz TRDI Rio Grande acoustic Doppler current profiler (ADCP) in mode 12 with 25 centimeter bins from a moving boat. The data were georeferenced with a Trimble AG132 differential Global Positioning System (GPS) receiver with submeter accuracy. The data were processed in the Velocity Mapping Toolbox (Parsons and others, 2013) to obtain a mean velocity field for each cross section from individual transects at each cross section. These data were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS), and were concurrent with a dye-tracing study. NOTE: Any data assigned a value of "-9999" are invalid or missing data and...
thumbnail
Bathymetric survey data of the Brandon Road Dam spillway was collected on May 27 and May 28, 2015 by the US Geological Survey (USGS) using Trimble Real-Time Kinematic Global Positioning System (RTK-GPS) equipment. The base station was set up over a temporarily installed survey pin on both days. This pin was surveyed into an existing NGS benchmark (PID: BBCN12) within the Brandon Road Lock property. In wadeable sections, a GPS rover with 2.0 meter range pole and flat-foot was deployed. In sections unable to be waded, a 2.0 meter range pole was fix-mounted to a jon boat, and a boat-mounted Acoustic Doppler Current Profiler (ADCP) was used to collect the depth data. ADCP depth data were reviewed in the WinRiver II...
thumbnail
These data were collected using a 1200 kHz TRDI Rio Grande acoustic Doppler current profiler (ADCP) in mode 12 with 25 centimeter bins from a moving boat. The data were georeferenced with a Hemisphere V102 differential Global Positioning System (GPS) receiver with submeter accuracy. The data were processed in the Velocity Mapping Toolbox (Parsons and others, 2013) to obtain a mean velocity field for each cross section from individual transects at each cross section. These data were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS), and were concurrent with a dye-tracing study. NOTE: Any data assigned a value of "-9999" are invalid or missing data and...
thumbnail
These data were collected using a 1200 kHz TRDI Rio Grande acoustic Doppler current profiler (ADCP) in mode 12 with 25 centimeter bins from a moving boat. The data were georeferenced with a Trimble AG132 differential Global Positioning System (GPS) receiver with submeter accuracy. The data have been depth-averaged over the entire measured portion of the water column, temporally averaged over 5-second intervals to reduce noise, and exported as a .csv file using the Velocity Mapping Toolbox (Parsons and others, 2013). These data were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS), and were concurrent with a dye-tracing study. NOTE: Any data assigned...
thumbnail
Flow discharges were measured in the Des Plaines River from approximately river mile 286 to river mile 284 on October 19–21, 2015 using Teledyne Rio Grande 1200 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with differential GPS receivers with submeter accuracy. These flow discharge measurements were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS), and were concurrent with a dye-tracing study. The discharge measurements included here were collected in the following locations: immediately upstream, across, and immediately downstream of the NRG Energy Joliet Power Station right descending bank intake (North Intake) immediately...
thumbnail
Water velocities were measured in the Des Plaines River from approximately river mile 286 to river mile 284 on October 19–21, 2015 using Teledyne Rio Grande 1200 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with differential GPS receivers with submeter accuracy. These velocity data were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS), and were concurrent with a dye-tracing study. ADCP data were collected in the approach channel of the Brandon Road Lock and downstream in the main channel of the Des Plaines River to determine the spatial distribution of depth-averaged velocity in the river on October 19–21, 2015. The data...
thumbnail
These data were collected using a 1200 kHz TRDI Rio Grande acoustic Doppler current profiler (ADCP) in mode 12 with 25 centimeter bins from a moving boat. The data were georeferenced with a Trimble AG132 differential Global Positioning System (GPS) receiver with submeter accuracy. The data have been depth-averaged over the entire measured portion of the water column, temporally averaged over 5-second intervals to reduce noise, and exported as a .csv file using the Velocity Mapping Toolbox (Parsons and others, 2013). These data were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS), and were concurrent with a dye-tracing study. NOTE: Any data assigned...
thumbnail
These data were collected using a 1200 kHz TRDI Rio Grande acoustic Doppler current profiler (ADCP) in mode 12 with 25 centimeter bins from a moving boat. The data were georeferenced with a Trimble AG132 differential Global Positioning System (GPS) receiver with submeter accuracy. The data have been depth-averaged over the entire measured portion of the water column, temporally averaged over 5-second intervals to reduce noise, and exported as a .csv file using the Velocity Mapping Toolbox (Parsons and others, 2013). These data were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS), and were concurrent with a dye-tracing study. NOTE: Any data assigned...
thumbnail
An Insitu Level Troll 500 was deployed in the Brandon Road Lock chamber (BRLD) near Rockdale, Illinois between 12:09 Central Daylight Time (CDT) on October 19, 2015 and 14:57 CDT October 21, 2015 to monitor water-surface elevation in the lock chamber during a U.S. Geological Survey dye study conducted on October 20, 2015. The duration of the deployment included a day prior to and a day following the dye study to capture the lock operations leading up to and following the dye study. The instrument was deployed within conduit placed inside the ladder well near the 500-foot station on the right wall of the lock chamber (when looking downstream). At the time of deployment, the Level Troll was calibrated to the water...


    map background search result map search result map Acoustic Doppler current profiler velocity data collected in the approach channel of Brandon Road Lock and Dam in 2015 Spatial distribution of depth-averaged velocity measured in the Des Plaines River, Illinois (October 19, 2015) Survey of velocity at cross sections in the Des Plaines River near Brandon Road Lock and Dam, Joliet, Illinois (October 19, 2015) Spatial distribution of depth-averaged velocity measured in the Des Plaines River, Illinois (October 20, 2015) Survey of velocity at cross sections in the Des Plaines River near Brandon Road Lock and Dam, Joliet, Illinois (October 20, 2015) Spatial distribution of depth-averaged velocity measured in the Des Plaines River, Illinois (October 21, 2015) Water surface elevation in the Brandon Road Lock chamber near Rockdale, Illinois (October 19-21, 2015) Bathymetric survey of the Brandon Road Dam Spillway, Joliet, Illinois Miscellaneous flow discharge measurements collected downstream of Brandon Road Lock and Dam Water surface elevation in the Brandon Road Lock chamber near Rockdale, Illinois (October 19-21, 2015) Bathymetric survey of the Brandon Road Dam Spillway, Joliet, Illinois Acoustic Doppler current profiler velocity data collected in the approach channel of Brandon Road Lock and Dam in 2015 Spatial distribution of depth-averaged velocity measured in the Des Plaines River, Illinois (October 19, 2015) Survey of velocity at cross sections in the Des Plaines River near Brandon Road Lock and Dam, Joliet, Illinois (October 19, 2015) Spatial distribution of depth-averaged velocity measured in the Des Plaines River, Illinois (October 20, 2015) Survey of velocity at cross sections in the Des Plaines River near Brandon Road Lock and Dam, Joliet, Illinois (October 20, 2015) Spatial distribution of depth-averaged velocity measured in the Des Plaines River, Illinois (October 21, 2015) Miscellaneous flow discharge measurements collected downstream of Brandon Road Lock and Dam