Filters: Tags: groundwater (X) > partyWithName: Denis R LeBlanc (X)
19 results (111ms)
Filters
Date Range
Extensions Types
Contacts
Categories Tag Types Tag Schemes |
This dataset contains field measurements of lakebed groundwater temperatures collected during three surveys in July 2008, August 2014, and August 2015, by using a handheld thermocouple probe and GPS at a permeable reactive barrier at Ashumet Pond, Falmouth, MA. The comma-separated file includes unique site identifiers, locations of measurement points, temperatures, dates, and types of measurement (groundwater, surface water, or control). Also included are ESRI raster datasets for each measurement date for (1) interpolated lakebed groundwater temperatures, and (2) interpolated lakebed groundwater temperatures normalized to the surface water temperature at the time of measurement. This data release is provided...
This data release provides a comprehensive dataset of sampling-site characteristics and baseline groundwater-quality data collected from a network of multilevel sampling wells installed in a densely developed coastal neighborhood undergoing a conversion from onsite septic systems to municipal sewering. Groundwater samples were collected during multiple events from a total of 227 well screens at 15 locations using a peristaltic pump between June 2016 and September 2021. Samples were collected and preserved following methods documented in the U.S. Geological Survey National Field Manual (variously dated) and Savoie and others (2012). This dataset provides well construction information, groundwater levels, water-quality...
Categories: Data,
Data Release - Revised;
Tags: Falmouth,
Mara Vista,
Massachusetts,
USGS Science Data Catalog (SDC),
groundwater,
This dataset contains field measurements of temperature in shallow vertical profiles beneath a lake-bottom in the vicinity of a permeable reactive barrier (PRB) at Ashumet Pond, Falmouth, MA. From August 21, 2015 – September 3, 2015 vertical temperature profilers designed to quantify groundwater upwelling dynamics were installed at seven locations. Hollow stainless steel pipes (2.5 cm OD) were slotted horizontally to allow installation of iButton thermal data loggers (Maxim Integrated DS1922L, 0.0625 oC precision) protected with waterproof silicone caulking. The temperature profilers were gently tapped into the cobbly bed by first driving guide-hole of slightly smaller diameter. After installation, the thermal loggers...
Categories: Data;
Tags: Cape Cod,
Falmouth,
Massachusetts,
groundwater,
groundwater and surface-water interaction,
This dataset contains field measurements of direct groundwater seepage by using half-barrel style seepage meters permanently installed in a lake-bottom permeable reactive barrier (PRB) at Ashumet Pond, Falmouth, MA. The meters are a modified version of a standard half-barrel seepage meter. Each meter consists of a 208-L polyethylene, corrosion-inhibiting drum cut to a length of 0.8 m and fitted with a removable 0.56-m-diameter lid. A 1.3-cm-diameter hole was drilled into each lid to allow outflow or inflow to be measured. During installation, the top rim of each barrel was positioned to be at the expected grade after backfilling. Between 2004 and 2015, seepage rates at each meter were measured annually, with the...
Categories: Data;
Tags: Cape Cod,
Falmouth,
Massachusetts,
groundwater,
groundwater and surface-water interaction,
On June 5, 2015, transient electromagnetic (TEM) data were acquired on the baseball field at the East Falmouth, Massachusetts Elementary School approximately 30 m north the well MA-FWS-750. Transient electromagnetic induction (TEM) surveys provide resistivity soundings of the subsurface, which can be related to lithology and hydrogeology. Electrical current is cycled through a wire placed on the land surface in a transmitter loop (Tx), which in turn produces a static magnetic field. When the current is abruptly terminated, an instantaneous current is induced in the earth, and it moves downward and outward as the induced current decays with time. The decay is controlled by the resistivity of the earth. One or more...
This data release presents chemical and biological results from an investigation of the uptake of per- and polyfluoroalkyl substances (PFAS) from groundwater contaminated by fire training activities on Cape Cod, Massachusetts conducted from July to August 2019. An exposure experiment was conducted at an a PFAS contaminated site (FTA-1) near the fire training area (FTA). To assess the tissue-specific uptake characteristics of the mixture of PFAS present in the groundwater from the FTA-1 site, a 21-day mobile laboratory exposure experiment was conducted. Details for the groundwater sampling sites and well construction are presented (Table 1). The PFAS mixture concentrations and composition in groundwater and in fish...
Categories: Data;
Types: Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Biotic concentration,
Cape Cod,
Environmental Health,
Fathead minnows,
Fire training area,
This U.S. Geological Survey data release provides a comprehensive dataset of water-quality data and sampling-site characteristics collected in 1978–2018 during a study of the effects of land disposal of treated wastewater on groundwater quality in an unconsolidated sand and gravel aquifer on Cape Cod, Massachusetts. Treated sewage-derived wastewater was discharged to rapid-infiltration beds at Joint Base Cape Cod for nearly 60 years before the disposal was moved to a different location in December 1995. The discharge formed a plume of contaminated groundwater that partly discharges to a glacial kettle lake about 1,600 feet from the beds and extends about 4.5 miles toward coastal saltwater bodies at Vineyard Sound....
Categories: Data;
Types: Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Barnstable County,
Bourne,
Cape Cod,
Falmouth,
Mashpee,
This U.S. Geological Survey (USGS) data release provides a comprehensive dataset of water-quality results, physical-parameter measurements, hydrologic measurements, and site information collected to study the nature and extent of water quality along groundwater flow paths adjacent to glacial-kettle lakes on Cape Cod, Massachusetts. Water-quality samples were collected in 2003, 2005, and 2012 through 2018 in and near seven kettle lakes located on western Cape Cod, with most of the data collected in 2015-2017 from Ashumet Pond, which is located in the towns of Falmouth and Mashpee. Data were also collected at other lakes to compare the lake-specific influences of geochemistry and hydrology on the downgradient groundwater...
This data set contains one-dimensional water flux (specific discharge, or Darcy flux, q) data calculated from vertical temperature profile data. The flux was calculated from paired time series of temperature from the shallowest and the deepest iButton loggers at each site described in child item "Field measurements of lake-bottom groundwater temperatures from vertical temperature profiles at four groundwater flow-through glacial kettle lakes, western Cape Cod, Massachusetts, 2016–18" by using the automated VFLUX software (version 2.0.0) run in Matlab. VFLUX 2.0.0 can be downloaded for free at http://hydrology.syr.edu/vflux/. The data are presented as time-varying continuous records of flux calculated by three methods:...
This data release includes geospatial datasets, comma separated values (.csv) files, and associated FGDC-compliant metadata representing data collected between 2004 and 2015 as part of a study of groundwater/surface-water interaction in the area of a lake-bottom permeable reactive barrier at Ashumet Pond, Falmouth, Massachusetts. The data sets are organized by type: (1) Fiber-Optic Distributed Temperature Sensing (FO-DTS) measurements of lake-bottom groundwater temperatures collected May 30-31, 2007, (2) Seepage meter data collected between November 2004 and August 2015, (2) Vertical temperature profile data collected between August 21, 2015 and September 3, 2015, and (4) Lakebed temperature measurements collected...
This dataset presents descriptions of sediments collected from a boring drilled to bedrock near Nantucket Sound in East Falmouth, Cape Cod, Massachusetts. There are four types of descriptions—units, features, subsamples, and grain-size distributions: 1) Units correspond to “lithostratigraphic units” described by Hull and others (2019). Units are vertically continuous zones of generally similar sediment type. They range from 1 to 100 feet thick. The top and bottom of each unit is given in feet relative to depth below land surface. 2) Features are described as “lithostratigraphic features” by Hull and others (2019). Features are discrete zones of very similar sediment 0.1 to 5.0 feet thick. A single unit can encompass...
Categories: Data;
Types: Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: East Falmouth,
Quaternary,
earth history,
groundwater,
hydrology,
Temperature sensors were installed in the lake-bottom sediments of Ashumet, Long (Centerville), Santuit, and Shubael Ponds, all on Cape Cod, Massachusetts, three times during 2016–18 to obtain shallow vertical temperature profiles. The sensors were installed at 11 sites from July 27 to October 13, 2016; 10 sites from September 19 to October 11, 2017; and 2 sites from February 13 to February 23, 2018. The vertical temperature profilers are designed to collect temperature data at different depths in the lake-bottom sediments for the calculation of downward groundwater seepage rates, as described in child item "Calculations of lake-bottom seepage rates from vertical temperature profiles at four groundwater flow-through...
The U.S. Geological Survey Toxic Substances Hydrology Program Cape Cod Research site has been the subject of intensive hydrological and geochemical investigations. The site has multiple sources of poly- and perfluoroalkyl substances (PFASs), including perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA), for which the U.S. Environmental Protection Agency has issued health advisories because of potential adverse human health effects. During 2014 and 2015, groundwater contamination by PFASs from a fire-training area and a wastewater treatment facility effluent infiltration beds, located on Joint Base Cape Cod, was assessed by collecting groundwater samples and sediment cores (Figures 1 and 2). The water...
Categories: Data,
Data Release - Revised;
Tags: Cape Cod,
Environmental Health,
Geochemistry,
Joint Base Cape Cod,
Massachusetts,
In March 2016, the U.S. Geological Survey drilled a borehole, MA-FSW-750-0100, through the unconsolidated sediments and 1.5 m into the bedrock in East Falmouth, Massachusetts, to improve understanding of the glacial history and hydrologic properties of the Cape Cod aquifer. Prior to drilling, candidate sites were investigated using surface geophysical methods. Passive seismic horizontal-to-vertical spectral ratio (HVSR) methods were used to estimate the depth of the unconsolidated deposits over bedrock. Transient electromagnetic (TEM) surveys were conducted to characterize the lithology and salinity of formation water in the subsurface, which was used to plan the borehole completion. The specific conductance of...
A pulsed magnetic resonance borehole tool was used to characterize hydraulic properties of the aquifer. Borehole nuclear magnetic resonance (bNMR) logs were collected to measure the water content and to estimate the pore-size distribution and hydraulic conductivity (K) over the depth of the borehole. The bNMR data were collected July 25-26, 2016, and were processed August 2016.
In March 2016, the U.S. Geological Survey drilled a borehole, MA-FSW-750, through the unconsolidated sediments and 1.5 m into the bedrock in East Falmouth, Massachusetts, to improve understanding of the glacial history and hydrologic properties of the Cape Cod aquifer. Polyvinyl casing was set through the overburden and into the bedrock. About 10 days after borehole MA-FSW-750 was drilled, it was logged with geophysical methods including natural gamma radiation and electromagnetic induction (EMI) logs to identify changes in the lithology and fluid properties of the subsurface. In addition, the gamma and EMI logs were collected about 100 days after drilling, which allowed the drilling fluids to be displaced and natural...
Passive seismic horizontal-to-vertical spectral ratio (HVSR) methods were used to estimate the depth of the unconsolidated deposits over bedrock. The HVSR method uses a three-component seismometer to measure the vertical and two horizontal components of ambient seismic noise. Seismic noise in the range of ~0.1 to 1 Hertz (Hz) is caused by ocean waves, large regional storms, and tectonic sources. A resonance frequency (f0) is induced in the unconsolidated deposits when there is a substantial contrast (> 2:1) in shear-wave acoustic impedance between the overburden and the bedrock. The f0 is determined from the analysis of the spectral ratio of the horizontal and vertical components of the seismic data. The thickness...
Locations of focused groundwater seepage to surface water are often hydrologically and ecologically important. Spatially focused or ‘preferential’ seepage can be identified as anomalous cold zones compared to warmer adjacent bank and surface water features (in summer). The temperature of deeper groundwater on Cape Cod is expected to approximate 11 °C year-round, yielding a relatively cold signature where groundwater emerges from the saturated sediment interface. Recent advances in thermal infrared imaging allow efficient real-time scanning for cold anomalies that may be associated with preferential seepage zones, and direct temperature measurements can be collected within the sediments of these zones to better capture...
Categories: Data;
Types: Downloadable,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
Shapefile;
Tags: Cape Cod,
Coonamessett River, Cape Cod, Massachusetts,
Groundwater,
Massachusetts,
USGS Science Data Catalog (SDC),
|
|