Filters: Tags: Geochemical Sample (X) > Extensions: NGGDPP Item (X)
83,297 results (76ms)
Filters
Date Range
Categories |
179 samples were analyzed for silver and copper using Atomic Absorption Spectroscopy after aqua regia digestion and for trace elements using Instrumental Nuetron Activation Analysis. 179 samples were analyzed for tin using X-ray Fluorescence Spectroscopy after pressed pellet preparation. Variable detection limits due to sample composition.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed using inductively coupled plasma. Samples with highly anomalous visible quantities of gold, silver, platinum group elements, copper, lead, zinc, or antimony were further analyzed by fire assay/or atomic absorption.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed using inductively coupled plasma. Samples with highly anomalous visible quantities of gold, silver, platinum group elements, copper, lead, zinc, or antimony were further analyzed by fire assay/or atomic absorption.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed by inductively coupled plasma (ICP) spectroscopy. Samples with visible quantities of either gold, silver, platnium group elements, copper, lead, zinc, tin, molybdemum, chromium, nickel, or antimony had fire assay or atomic absorption analyses performed for those elements.
Categories: Physical Item;
Tags: Geochemical Sample
Major- and trace-element values for rock samples were determined by ALS Geochemistry method MEMS61: Four-acid digestion followed by inductively-coupled plasma�atomic emission spectrometry (ICPAES) and inductively-coupled plasma�mass spectroscopy (ICP-MS); Au values were analyzed using flux digestion and fire assay and ICP-AES (ALS Geochemistry method Au-ICP21). Samples that exceeded detection limits for elements of interest were reanalyzed using specific elemental tests. Over-limit values for Pb were analyzed using four-acid digestion followed by inductively-coupled plasma�atomic emission spectrometry (ALS Geochemistry method ME-OG62). Selected samples were analyzed for were Pt, Pd, and Au using lead oxide fire...
Categories: Physical Item;
Tags: Geochemical Sample
For whole-rock geochemistry samples, major and minor oxides were analyzed by lithium metaborate fusion digestion and ICP-AES (ALS Geochemistry method ME-ICP06). Trace elements, including rare-earth elements, were determined using lithium metaborate fusion digestion and ICP-MS (ALS Geochemistry method ME-MS81). Ag, Cd, Co, Cu, Li, Mo, Ni, Pb, Sc, and Zn were determined by four-acid digestion and ICP-AES (ALS Geochemistry method ME-4ACD81); and As, Bi, Hg, In, Re, Sb, Se, Te, and Tl were determined by aqua regia digestion followed by ICP-MS (ALS Geochemistry method ME-MS42). Total C and S were analyzed by Leco furnace (ALS Geochemistry methods C-IR07 and S-IR08, respectively). Au values were analyzed using flux digestion...
Categories: Physical Item;
Tags: Geochemical Sample
24 samples were analyzed by the following methods and digestions: titrimetric analysis and gravimetric analysis. 24 samples were analyzed for major oxides by XRF after lithium tetraborate fusion. 24 samples were analyzed for trace elements by XRF after pressed pellet preparation. 24 samples were analyzed by Specific Ion after Na2CO3-KNO3 fusion. Fe2O3 % is calculated.
Categories: Physical Item;
Tags: Geochemical Sample
90 samples were analyzed by the following methods and digestions: INAA, ICP after HF-HNO3-HClO4 acid digestion with HCl leach, AA after HNO3-HCl hot extraction. 1 sample was analyzed for DC Plasma Emission after fire assay. 52 samples were analyzed for Specific Ion after Na2CO3-KNO3-fusion. Elevated detection limits are due to high levels of Th and U.
Categories: Physical Item;
Tags: Geochemical Sample
90 samples were analyzed by the following methods and digestions: INAA, ICP after HF-HNO3-HClO4 acid digestion with HCl leach, AA after HNO3-HCl hot extraction. 1 sample was analyzed for DC Plasma Emission after fire assay. 52 samples were analyzed for Specific Ion after Na2CO3-KNO3-fusion. Elevated detection limits are due to high levels of Th and U.
Categories: Physical Item;
Tags: Geochemical Sample
142 samples were analyzed by the following methods and digestions: INAA, AA after HNO3-HCl hot extraction. 109 samples were analyzed by CVAA after HNO3-HCl-SnSO4 acid digestion, AA with Muliti-Acid MIBK and XRF. 90 samples were analyzed by DC Plasma Emission after NaOH fusion. 89 samples were analyzed by ICP after HF-HNO3-HClO4 acid digestion with HCl leach. Assay of High Zn to follow on V91-20128.6
Categories: Physical Item;
Tags: Geochemical Sample
142 samples were analyzed by the following methods and digestions: INAA, AA after HNO3-HCl hot extraction. 109 samples were analyzed by CVAA after HNO3-HCl-SnSO4 acid digestion, AA with Muliti-Acid MIBK and XRF. 90 samples were analyzed by DC Plasma Emission after NaOH fusion. 89 samples were analyzed by ICP after HF-HNO3-HClO4 acid digestion with HCl leach. Assay of High Zn to follow on V91-20128.6
Categories: Physical Item;
Tags: Geochemical Sample
827 samples were analyzed for major and minor oxides using X-ray Fluorescence after lithium metaborate fusion; for gold on a 30-gram split using Atomic Absorption Spectroscopy after Fire Assay; for trace elements using Inductively Coupled Plasma - Atomic Emission Spectroscopy following HCl:HNO3 (3:1) acid digestion. XRF analysis was performed on raw (non-fused) rock samples by Inco Limited's laboratory in Copper Cliff, Ontario for barium, niobium, strontium, yttrium and zirconium.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed using inductively coupled plasma. Samples with highly anomalous visible quantities of gold, silver, platinum group elements, copper, lead, zinc, or antimony were further analyzed by fire assay/or atomic absorption.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed by inductively coupled plasma (ICP) spectroscopy. Samples with visible quantities of either gold, silver, platnium group elements, copper, lead, zinc, tin, molybdemum, chromium, nickel, or antimony had fire assay or atomic absorption analyses performed for those elements.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed using inductively coupled plasma. Samples with highly anomalous visible quantities of gold, silver, platinum group elements, copper, lead, zinc, or antimony were further analyzed by fire assay/or atomic absorption.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed by inductively coupled plasma (ICP) spectroscopy. Samples with visible quantities of either gold, silver, platnium group elements, copper, lead, zinc, tin, molybdemum, chromium, nickel, or antimony had fire assay or atomic absorption analyses performed for those elements.
Categories: Physical Item;
Tags: Geochemical Sample
142 samples were analyzed by the following methods and digestions: INAA, AA after HNO3-HCl hot extraction. 109 samples were analyzed by CVAA after HNO3-HCl-SnSO4 acid digestion, AA with Muliti-Acid MIBK and XRF. 90 samples were analyzed by DC Plasma Emission after NaOH fusion. 89 samples were analyzed by ICP after HF-HNO3-HClO4 acid digestion with HCl leach. Assay of High Zn to follow on V91-20128.6
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed by inductively coupled plasma (ICP) spectroscopy. Samples with visible quantities of either gold, silver, platnium group elements, copper, lead, zinc, tin, molybdemum, chromium, nickel, or antimony had fire assay or atomic absorption analyses performed for those elements.
Categories: Physical Item;
Tags: Geochemical Sample
Silver, copper, lead, zinc, and molybdenum were analyzed by ICP-AES and following a digestion of a multi acid (total digestion) solution. The laboratories analyzed the remaining elements by ICP-AES. In most instances, when the results of samples analyzed by this method exceeded the upper detection limits, the samples were not reanalyzed, but results were reported as being greater than the corresponding upper detection limit. However, values above ICP-AES detection limits were obtained for some samples using low-level assay methods consisting of a multi acid digestion and AA finish, with results reported in percent.
Categories: Physical Item;
Tags: Geochemical Sample
Rock samples were analyzed by inductively coupled plasma (ICP) spectroscopy. Samples with visible quantities of either gold, silver, platnium group elements, copper, lead, zinc, tin, molybdemum, chromium, nickel, or antimony had fire assay or atomic absorption analyses performed for those elements.
Categories: Physical Item;
Tags: Geochemical Sample
|
![]() |