Filters: Tags: Water Purification (X)
6 results (7ms)
Filters
Date Range
Extensions Types Contacts
Categories Tag Types |
First and second law of thermodynamics have been used to analyze the performance of an experimental heat transformer used for water purification. The pure water is produced in the auxiliary condenser delivering an amount of heat, which is recycled into the heat transformer increasing the heat source temperatures and also the internal, external and exergy coefficients of performance. The theoretical and experimental study was divided into two parts. In the first part, a second law analysis was carried out to the experimental system showing that the absorber and the condenser are the components with the highest irreversibilities. In the second part, with the results obtained from the second law analysis, new test...
Categories: Publication;
Types: Citation;
Tags: Distillation,
Exergy analysis,
Heat transformers,
Water purification
Clean water is important for a variety of uses, including drinking, recreation, and as habitat for aquatic species. Nonpoint-source pollution, such as nutrients, sediment, and pesticides from agricultural runoff, is a major cause of impaired water quality in the United States . Vegetation and soil in natural land cover help to remove pollutants from runoff water before it reaches streams and other waterways by slowing water flow and physically trapping sediment. To assess the spatial distribution of water purification potential in the southeastern United States, we mapped the demand for purification as the total area of agricultural land and the supply of natural land cover in the flowpath over which water moves...
Types: Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Alabama (AL),
Arkansas (AR),
Florida (FL),
Georgia (GA),
Louisiana (LA),
To test the effect of geochemical heterogeneity on microorganism transport in saturated porous media, we measured the removal of two microorganisms, the bacteriophage PRD1 and oocysts of the protozoan parasite Cryptosporidium parvum, in flow-through columns of quartz sand coated by different amounts of a ferric oxyhydroxide. The experiments were conducted over ranges of ferric oxyhydroxide coating fraction of lambda = 0-0.12 for PRD1 and from lambda = 0-0.32 for the oocysts at pH 5.6-5.8 and 10(-4) M ionic strength. To determine the effect of pH on the transport of the oocysts, experiments were also conducted over a pH range of 5.7-10.0 at a coating fraction of lambda = 0.04. Collision (attachment) efficiencies...
Categories: Publication;
Types: Citation;
Tags: Animals,
Bacteriophage PRD1,
Biological Transport,
Cryptosporidium parvum,
Electron,
Soil treatment of wastewater has the potential to achieve high purification efficiency, yet the understanding and predictability of purification with respect to removal of viruses and other pathogens is limited. Research has been completed to quantify the removal of virus and bacteria through the use of microbial surrogates and conservative tracers during controlled experiments with three-dimensional pilot-scale soil treatment systems in the laboratory and during the testing of full-scale systems under field conditions. The surrogates and tracers employed included two viruses (MS-2 and PRD-1 bacteriophages), one bacterium (ice-nucleating active Pseudomonas), and one conservative tracer (bromide ion). Efforts have...
Categories: Publication;
Types: Citation;
Tags: Bacteriophages,
Escherichia coli,
Fluid,
Humans,
Pseudomonas,
First and second law of thermodynamics have been used to analyze the performance of an experimental heat transformer used for water purification. The pure water is produced in the auxiliary condenser delivering an amount of heat, which is recycled into the heat transformer increasing the heat source temperatures and also the internal, external and exergy coefficients of performance. The theoretical and experimental study was divided into two parts. In the first part, a second law analysis was carried out to the experimental system showing that the absorber and the condenser are the components with the highest irreversibilities. In the second part, with the results obtained from the second law analysis, new test...
Categories: Publication;
Types: Citation;
Tags: Distillation,
Exergy analysis,
Heat transformers,
Water purification
First and second law of thermodynamics have been used to analyze the performance of an experimental heat transformer used for water purification. The pure water is produced in the auxiliary condenser delivering an amount of heat, which is recycled into the heat transformer increasing the heat source temperatures and also the internal, external and exergy coefficients of performance. The theoretical and experimental study was divided into two parts. In the first part, a second law analysis was carried out to the experimental system showing that the absorber and the condenser are the components with the highest irreversibilities. In the second part, with the results obtained from the second law analysis, new test...
Categories: Publication;
Types: Citation;
Tags: Distillation,
Exergy analysis,
Heat transformers,
Water purification
|
|