Skip to main content
Advanced Search

Filters: Tags: hydrodynamics (X)

384 results (675ms)   

View Results as: JSON ATOM CSV
thumbnail
A vented conductivity, temperature and depth sensor (CTD, InSitu Aqua Troll) was installed at site NR1 (N 47° 04’ 16.1”/W 122° 42’ 15.5”) and continuously measured water temperature, water depth, specific conductance, and salinity at 15-minute intervals from February 11, 2016 to July 18, 2016 (159 days). The sensor was replaced with a vented water-level logger (InSitu Level Troll) on July 19, 2016 and deployed until March 19, 2018 (608 days). The site is tidally influenced and located approximately 4.1 km upstream from the mouth of the Nisqually River and within the tidal prism. The elevation (NAVD88) of the top of the deployment pipe was surveyed by RTN-GPS. Tape-down measurements from the top of the pipe to the...
thumbnail
In 2016, the U.S. Fish and Wildlife Service, U.S. Geological Survey, and U.S. Army Corps of Engineers undertook a large-scale interagency field study to determine the influence of commercial barge vessels on the efficacy of the Electric Dispersal Barrier System (EDBS) in the Chicago Sanitary and Ship Canal (CSSC) in preventing fish passage. This study included a series of trials in which a tow, consisting of a tug vessel and six fully-loaded barges, transited the EDBS in both upstream-bound (n = 23) and downstream-bound (n = 22) directions. A 3,000 kHz SonTek Argonaut SW Acoustic Doppler Velocity Meter (ADVM) was mounted on the barge at the position of the rake-to-box junction. The ADVM faced outward from the side...
thumbnail
Water velocities and discharge were measured in the lock chamber and immediately downstream of Brandon Road Lock on the Des Plaines River at river mile 286 on December 9-10, 2014 using Teledyne RDI Rio Grande 600 and 1200 kHz acoustic Doppler current profilers (ADCP). The data were georeferenced with a differential GPS receiver with submeter accuracy. These ADCP measurements were collected in support of the US Army Corps of Engineers Great Lakes and Mississippi River Interbasin Study (GLMRIS). Velocity measurements were processed using the Velocity Mapping Toolbox (Parsons and others, 2013) to derive temporally- and spatially-averaged water velocity values. Discharge measurements were processed with the QRev discharge...


map background search result map search result map Velocity profiling at the US Army Corps of Engineers Electric Dispersal Barrier in the Chicago Sanitary and Ship Canal during passage of fully loaded commercial tows in August 2016: Barge Mounted Argonaut SW Acoustic Doppler current profiler velocity and discharge measurements collected in and near the lock chamber of Brandon Road Lock and Dam, Joliet, Illinois, USA in December 2014 Water Data for Nisqually River at Site NR1 Velocity profiling at the US Army Corps of Engineers Electric Dispersal Barrier in the Chicago Sanitary and Ship Canal during passage of fully loaded commercial tows in August 2016: Barge Mounted Argonaut SW Acoustic Doppler current profiler velocity and discharge measurements collected in and near the lock chamber of Brandon Road Lock and Dam, Joliet, Illinois, USA in December 2014