Filters: Tags: {"scheme":"USGS Chloride Flux Yellowstone National Park"} (X) > Types: OGC WMS Layer (X)
13 results (13ms)
Filters
Date Range
Types Contacts
Categories Tag Types Tags (with Scheme=USGS Chloride Flux Yellowstone National Park) |
Boiling River at Mammoth (YBOI), Yellowstone National Park Sample Collection: Samples were collected near the USGS stream gage 06190540 (Latitude 44°59'05.83", Longitude 110°41'18.20" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses: Concentrations...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
Falls River near Squirrel, Idaho (YFAL) Sample Collection: Samples were collected near the USGS stream gage 13046995 (Latitude 44°03'43", Longitude 111°09'07" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses: Concentrations of chloride, fluoride,...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Geothermal,
Yellowstone National Park,
chloride flux
Yellowstone River at Corwin Springs, MT (YYCR) Sample Collection: Samples were collected near the USGS stream gage 06191500 (Latitude 45°06'43.63", Longitude 110°47'37.20" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses: Concentrations of chloride,...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
The U.S. Geological Survey (USGS) and the National Park Service (NPS) have collaborated on monitoring the chloride flux in the major rivers of Yellowstone National Park by periodically sampling the rivers and analyzing chloride concentrations in discrete water samples since the 1970's. However, restrictions of winter travel, great distances between sites, and sampling and analytical costs have limited collection to approximately 28 samples per site annually. Electrical conductivity data can be used as a proxy for chloride concentrations in many of the major rivers of Yellowstone National Park. Electrical conductivity is a measure of the ability of water to pass an electrical current, and it is affected by the presence...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: USGS Science Data Catalog (SDC),
Water Resources,
Yellowstone National Park,
electrical conductivity,
specific conductance
Firehole River near Old Faithful, WY (YFOF), Yellowstone National Park Sample Collection: Samples were collected near the USGS stream gage 06036805 (Latitude 44°27'33.71", Longitude 110°49'18.25" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses:...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
Yellowstone River at Yellowstone Lake Outlet (YYFB), Yellowstone National Park Sample Collection: Samples were collected near the USGS stream gage 06186500 (Latitude 44°34'01.53", Longitude 110°22'49.46" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses:...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
Firehole River near Madison Junction (YFIR), Yellowstone National Park Sample Collection: Samples were collected near the USGS stream gage 06036905 (Latitude 44°37'12.66", Longitude 110°51'48.61" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses:...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
The Yellowstone Volcano Observatory (YVO) was established as a collaboration between the U.S. Geological Survey and Yellowstone National Park "To strengthen the long-term monitoring of volcanic and earthquake unrest in the Yellowstone National Park region." Yellowstone National Park is underlain by a voluminous magmatic system overlain by the most active hydrothermal system on Earth. Tracking changes in water and gas chemistry is of great importance because anomalous fluxes might signal one of the earliest warnings of volcanic unrest. Because of the tremendous number, chemical diversity, and large aerial coverage of Yellowstone's thermal features, it remains daunting to monitor individual features that might serve...
Madison River near West Yellowstone, MT (YMAD), Yellowstone National Park Sample Collection: Samples were collected near the USGS stream gage 06037500 (Latitude 44°39'25.46", Longitude 111°04'04.67" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses:...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
Henrys Fork near Ashton, Idaho (YHEN) Sample Collection: Samples were collected near the USGS stream gage 13046000 (Latitude 44°04'11", Longitude 111°30'38" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses: Concentrations of chloride, fluoride,...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
Gibbon River at Madison Junction (YGIB), Yellowstone National Park Sample Collection: Samples were collected near the USGS stream gage 06037100 (Latitude 44°38'26.88", Longitude 110°51'39.83" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses: Concentrations...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
Snake River above Jackson Lake at Flagg Ranch, WY (YSNA) Sample Collection: Samples were collected near the USGS stream gage 13010065 (Latitude 44°05'56", Longitude 110°40'03" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample Analyses: Concentrations of chloride,...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
Gardner River near Mammoth (YGAR), Yellowstone National Park Sample Collection: Samples were collected four kilometers downstream from the USGS stream gage 06191000 (Latitude 45°01'2.4", Longitude 110°41'37.2" NAD83). At the time of collection, all waters samples were filtered through a syringe filter (0.45-micrometer). Two splits of the filtered water were retained for chemical analyses, including an unacidified (FU) sample for determination of anion concentrations and a nitric acid preserved (FA; 1% volume-to-volume concentrated trace-metal grade nitric acid) sample for cation and trace metal analyses. During sample collection, the water temperature, specific conductance, and pH were often measured. Sample...
Categories: Data;
Types: Citation,
Map Service,
OGC WFS Layer,
OGC WMS Layer,
OGC WMS Service;
Tags: Boiling River,
Geothermal,
Yellowstone National Park,
chloride flux
|
|